Machine à ultrasons Doppler de couleur portable pour petit organe
$2100-3500 /Set/Sets
Type de paiement: | T/T |
Incoterm: | FOB |
Quantité de commande minimum: | 5 Set/Sets |
transport: | Ocean,Land,Express,Air |
Hafen: | Shenzhen,Ningbo,Shanghai |
$2100-3500 /Set/Sets
Type de paiement: | T/T |
Incoterm: | FOB |
Quantité de commande minimum: | 5 Set/Sets |
transport: | Ocean,Land,Express,Air |
Hafen: | Shenzhen,Ningbo,Shanghai |
Modèle: MDK-680
marque: Échographie unie
Lieu D'origine: Chine
Forme De Pouvoir: Électricité
Service De Garantie: 1 année
Service Après-vente: Pièces de rechange gratuites, Assistance technique en ligne
Matériel: métal, Plastique
Classification Des Dispositifs Médicaux: Classe II
Brand: United Ultrasound
Monitor Size: 12 inch
Gray Scale: 256 levels
Depth: ≥300mm
Channels: 32
Operating System: Windows 7
Color: black
Unités de vente | : | Set/Sets |
Type de colis | : | Carton |
Machine à ultrasons Doppler couleur portable pour petit organe (MDK-680)
Dans les petits organes, comme la thyroïde, la glande mammaire et le globe oculaire, l'échographie de couleur a une précision diagnostique évidente.
D'un certain point de vue, la sonde de 10 MHz a été plus claire que le doppler noir et blanc ordinaire sur 5 MHz, et la sonde est beaucoup plus claire. Le diagnostic et le diagnostic différentiel des lésions thyroïdiennes sont principalement basés sur l'approvisionnement en sang interne de la thyroïde, parmi laquelle l'image d'hyperthyroïdie est la plus typique et la plus spécifique.
Le goitre simple n'a montré aucun changement significatif par rapport au flux sanguin thyroïdien normal. La thyroïdite subaiguë, la thyroïdite de Hashimoto entre les deux, peut être distinguée, et par des nodules et une situation de débit sanguin périphérique peut être bien distinguée goitre nodulaire, adénome thyroïdien et cancer de la thyroïde, il est donc recommandé que le diagnostic thyroïdien ne soit pas clair, le patient a un Certaines capacités économiques peuvent effectuer des échographies de couleurs supplémentaires.
L'échographie de couleur mammaire est principalement utilisée dans le diagnostic différentiel du fibrome mammaire et du cancer du sein, et le globe oculaire a principalement une meilleure valeur dans le diagnostic des maladies vasculaires du globe oculaire.
Nos produits:
Scanner échographique noir et blanc
Scanner à ultrasons Doppler couleur
Scanner vétérinaire
No. |
Item |
Index |
<1> |
Depth |
≥300mm |
<2> |
Lateral Resolution |
≤1mm (Depth≤80mm) ≤2mm (80< Depth≤130mm) |
<3> |
Axial Resolution |
≤1mm (Depth≤80mm) ≤2mm (80< Depth≤130mm) |
<4> |
Blind Area |
≤5 mm |
<5> |
Geometry Position Precision |
horizontal≤5% vertical≤5% |
<6> |
Language |
English/Chinese |
<7> |
Channels |
32 |
<8> |
Displayer |
12” LED |
<9> |
External Display |
PAL, VGA, USB |
<10> |
Gray Scale |
256 levels |
<11> |
Voltage |
AC220V ±10% |
<12> |
Operating System |
Windows 7 |
<13> |
Scanning Mode |
B, B/B, 4B, B/M, M, B+C, B+D, B+C+D, PDI, CF, PW |
<14> |
Probe |
Probe sockets: 2 Probe frequency: 2.0MHz ~ 10.0MHz, 8-step frequency conversion |
<15> |
Adjustment parameters of color blood flow image |
Doppler frequency, sampling frame position and size, baseline, color gain, deflection angle, wall filtering, cumulative times, etc |
<16> |
Signal processing |
With dynamic filtering and quadrature demodulation With total gain adjustment Gain adjustment: 8-segment TGC The total gain of Type B, Type C and Type D can be adjusted respectively B/W image gain and color blood flow gain are adjustable respectively |
<17> |
Doppler |
Doppler baseline adjustment level 6 Pulse repetition frequency can be adjusted separately: CFM PWD With D linear speed regulation |
<18> |
Digital beam forming |
Continuous dynamic focusing of digital beam forming image Full range dynamic aperture of image Dynamic tracing of the whole image Weighted Sum of Image Whole Process Receiving Delay Support half step scanning and ± 10 ° linear receiving deflection angle Multi beam parallel processing technology |
<19> |
Basic measurement and calculation function |
Basic measurement in mode B: distance, angle, perimeter and area, volume, stenosis rate, histogram, cross-section |
|
|
Basic measurement of M-mode: heart rate, time, distance and speed |
|
|
Doppler measurement: time, heart rate, speed, acceleration |