Machine à ultrasons Doppler de couleur portable pour l'abdomen
$2100-3500 /Set/Sets
Type de paiement: | T/T |
Incoterm: | FOB |
Quantité de commande minimum: | 5 Set/Sets |
transport: | Ocean,Land,Air,Express |
Hafen: | Shenzhen,Ningbo,Shanghai |
$2100-3500 /Set/Sets
Type de paiement: | T/T |
Incoterm: | FOB |
Quantité de commande minimum: | 5 Set/Sets |
transport: | Ocean,Land,Air,Express |
Hafen: | Shenzhen,Ningbo,Shanghai |
Modèle: MDK-680
marque: Échographie unie
Color: white
Brand: United Ultrasound
Monitor Size: 12 inch
Gray Scale: 256 levels
Depth: ≥300mm
Channels: 32
Operating System: Windows 7
Lieu D'origine: Chine
Forme De Pouvoir: Électricité
Service De Garantie: 1 année
Service Après-vente: Pièces de rechange gratuites, Assistance technique en ligne
Matériel: métal, Plastique
Classification Des Dispositifs Médicaux: Classe II
Unités de vente | : | Set/Sets |
Type de colis | : | Carton |
Machine à ultrasons Doppler couleur portable pour l'abdomen (MDK-680)
Il est principalement utilisé dans le foie et les reins, mais il a une certaine valeur diagnostique auxiliaire pour distinguer les lésions bénignes et malignes dans la cavité abdominale, le cancer de la vésicule biliaire des grands polypes, une inflammation chronique et sévère, et la différence entre le canal biliaire commun et l'artère hépatique.
L'échographie de couleur peut être utilisée pour déterminer la taille de la lumière, la vitesse et la direction de l'écoulement interne et l'établissement d'une circulation collatérale dans la cirrhose du foie. Pour la sclérose nodulaire et le cancer du foie diffus, qui sont extrêmement difficiles à distinguer entre le noir et le blanc, il peut faciliter le diagnostic différentiel par exploration à haute fréquence et exploration du spectre sanguin.
Pour le diagnostic différentiel de l'espace hépatique bénin et malin occupant des lésions, les kystes et diverses tumeurs artérioveineuses ont une meilleure valeur diagnostique. Le cancer du foie primaire et le cancer du foie secondaire peuvent également être distingués par l'approvisionnement en sang interne.
L'échographie de couleur est principalement utilisée dans les reins pour les maladies vasculaires rénales. Comme mentionné ci-dessus, lorsque les manifestations cliniques sont une hématurie septale et indolore, la cause ne peut être trouvée, il existe de forts signes d'adaptation. Pour la sténose de l'artère rénale, l'une des causes courantes de l'hypertension secondaire, l'échographie de couleur peut faire un diagnostic clair essentiellement. Lorsque le débit sanguin à la sténose était de plus de 150 cm / s, la précision diagnostique a atteint 98,6% et la sensibilité était de 100%. D'un autre côté, c'est aussi le diagnostic différentiel du carcinome rénal, du carcinome transitionnel du bassin rénal et de la tumeur bénigne.
Nos produits:
Scanner échographique noir et blanc
Scanner à ultrasons Doppler couleur
Scanner vétérinaire
No. |
Item |
Index |
<1> |
Depth |
≥300mm |
<2> |
Lateral Resolution |
≤1mm (Depth≤80mm) ≤2mm (80< Depth≤130mm) |
<3> |
Axial Resolution |
≤1mm (Depth≤80mm) ≤2mm (80< Depth≤130mm) |
<4> |
Blind Area |
≤4 mm |
<5> |
Geometry Position Precision |
horizontal≤5% vertical≤5% |
<6> |
Language |
English/Chinese |
<7> |
Channels |
32 |
<8> |
Displayer |
12” LED |
<9> |
External Display |
PAL, VGA, USB |
<10> |
Gray Scale |
256 levels |
<11> |
Voltage |
AC220V ±10% |
<12> |
Operating System |
Windows 7 |
<13> |
Scanning Mode |
B, B/B, 4B, B/M, M, B+C, B+D, B+C+D, PDI, CF, PW |
<14> |
Probe |
Probe sockets: 2 Probe frequency: 2.0MHz ~ 10.0MHz, 8-step frequency conversion |
<15> |
Adjustment parameters of color blood flow image |
Doppler frequency, sampling frame position and size, baseline, color gain, deflection angle, wall filtering, cumulative times, etc |
<16> |
Signal processing |
With dynamic filtering and quadrature demodulation With total gain adjustment Gain adjustment: 8-segment TGC The total gain of Type B, Type C and Type D can be adjusted respectively B/W image gain and color blood flow gain are adjustable respectively |
<17> |
Doppler |
Doppler baseline adjustment level 6 Pulse repetition frequency can be adjusted separately: CFM PWD With D linear speed regulation |
<18> |
Digital beam forming |
Continuous dynamic focusing of digital beam forming image Full range dynamic aperture of image Dynamic tracing of the whole image Weighted Sum of Image Whole Process Receiving Delay Support half step scanning and ± 10 ° linear receiving deflection angle Multi beam parallel processing technology |
<19> |
Basic measurement and calculation function |
Basic measurement in mode B: distance, angle, perimeter and area, volume, stenosis rate, histogram, cross-section |
|
|
Basic measurement of M-mode: heart rate, time, distance and speed |
|
|
Doppler measurement: time, heart rate, speed, acceleration |
<20> |
Gynecological measurement and calculation function |
Measurement and calculation of uterus, left ovary, right ovary, left follicle, right follicle, etc |
<21> |
Obstetric measurement and calculation function |
G.A, EDD, BPD-FW, FL, AC, HC, CRL, AD, GS, LMP,HL,LV,OFD |
<22> |
Urology measurement and calculation function |
Measurement and calculation of left kidney, right kidney, bladder, residual urine volume, prostate, prostate specific antigen predicted value PPSA, prostate specific antigen density PSAD, etc |
<23> |
Product Size |
289×304×222mm |
<24> |
Carton Size |
395×300×410mm |
<25> |
N.W./ G.W. |
6kg/ 7kg |